E. Factory Default Settings
The factory default settings for firmware V1.3 for the ioLogik W5312 series, V1.5 for the ioLogik W5340 series,
and V1.2 for the ioLogik W5340-HSDPA series, are as follows:
IP address:
192.168.127.254
Netmask:
255.255.255.0
Gateway:
None
Communication Watchdog:
Disable
Modbus/TCP Alive Check:
ON
Modbus/TCP Timeout Interval:
60 sec
Server Address
None
Server Port
0
Baud Rate
9600
Data Bit
8
Stop Bit
1
Parity
None
Mode
RS-485, 2- Wire
Cellular Band
Auto
Cellular Operation Mode
On-Demand
Caller IDs
None
DI Mode:
DIO-0 to DIO-5 (W5340),
DI-0~DI-7, DIO8~11(W5312)
DI Safe Status:
Off
Filter Time for Counter:
10 × 0.5mS
Counter Trigger Type:
Lo to Hi
Counter Status:
Stop
AI Mode:
AI-0 to AI-3, +/- 10V
DO Mode:
DIO-6 to DIO-11(W5340),
DO-0~DO-7(W5312)
DO Safe Status:
Off
Pulse Low Width:
1
Pulse Hi Width:
1
No. of Pulses:
0 (continuous)
Filter Time for Counter:
10 × 0.5mS
Counter Trigger Type:
Lo to Hi
Counter Status:
Stop
Counter status:
Stop
Password:
“empty”