ioLogik Cellular Micro RTU Controller User’s Manual Seventh Edition, June 2012 www.moxa.com/product © 2012 Moxa Inc. All rights reserved.
ioLogik Cellular Micro RTU Controller Introduction 1-5 Product Features • Trouble-free connections to cellular networks • Automatic data
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-27 Repeat interval N/A “Timer = N sec” “THEN” action triggered THEN/ELSE Actions Unde
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-28 Timer STOP, START, RESTART Timer-x, x = 00 to 23 Max value: 4,294,967,295 seconds SNM
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-29 DO DO refers to the action of controlling the local digital output channels that react
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-30 AO Analog Output (AO) refers to the action of controlling the local Analog Output chan
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-31 Internal Register (Integer) Internal Register (Integer) represents a status flag to li
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-32 In the above figure, the “Used in:” column indicates this Timer is also used in Rule-0
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-33 Active Messages can be received by a program using standard sockets, Moxa MXIO librar
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-34 E-mail The E-mail function sends a customizable e-mail to one or more mail boxes or Bl
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-35 SMS Escalation, the SMS will be sent out in the sequence listed in the recipient list,
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-36 FTP Service The FTP Service function provides upload service for data log files stored
ioLogik Cellular Micro RTU Controller Introduction 1-6 LED Indicators Function Description Mark Power Input OFF: No Power PWR Green: Power On Ce
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-37 Activating the Rule-set Upload, Restart, and Run The rules that are displayed on the C
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-38 NOTE Since there are major structural changes between firmware versions, configuration
5 5. Planning and Assistance In this chapter, we will provide variety of real-life scenarios to help explain to you how to use the ioLogik W5300 to
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-2 Known Issues of Cellular Monitoring Systems Cellular technology is well-suited for
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-3 Known Issue 4: Large Power Consumption when Attached to Base Stations There will b
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-4 enables the ioLogik to report its I/O status, alarms, and log data actively. NOT
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-5 In the following sections, we illustrate how to set up an environment for the ioLo
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-6 Step 8: Start ioAdmin and add Active OPC server manually. Note: Selecting “AOPC”
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-7 Expanding Input/Output Channels Scenario: A monitoring system for a pumping statio
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-8 Step 9: After rebooting, log in to ioAdmin as Administrator and choose “I/O Config
ioLogik Cellular Micro RTU Controller Introduction 1-7 • 5-pin screw terminal block x 1 (for RS-485) • Documentation and software CD • Antenna NO
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-9 NOTE The following ioLogik E1200 models are supported for the I/O expansion: E1210
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-10 Step 7: Click on the ModScan32 icon to open ModScan32, as shown below. Step 8: C
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-11 Step 10: Look up the DI-0 and DI-1 Modbus addresses in the user’s manual, as show
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-12 Setup Procedure: Step 1: Open ioAdmin and set up your micro controller as follows
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-13 Record your I/O Data in the Data Log File Scenario: A cellular communication syst
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-14 Step 5: In the new profile, click Enable to activate the profile, specify the set
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-15 Step 7: Click the Save button. If you select Start for the initial state in Step
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-16 Step 3: Double click on the Click&Go rule entry. Step 4: In the IF Condition
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-17 Step 5: In the THEN Action, select FTP Service and specify which profile’s log fi
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-18 Step 7: On the Click&Go panel, click Run to activate the logic. The Log file
ioLogik Cellular Micro RTU Controller Introduction 1-8 SIM Control Voltage: 3 V LAN Ethernet: 1 x 10/100 Mbps, RJ45 Protection: 1.5 KV magnetic i
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-19 Connecting a Modbus/RTU Serial Device Attached to the ioLogik over a Cellular Net
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-20 Diagram Setup Procedure Step 1: Install the SCADA system and Active OPC server o
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-21 Updating Serial Tags to SCADA System with Active OPC Server over a Cellular Netwo
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-22 Step 8: After clicking OK, restart the ioLogik by right clicking the selected ioL
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-23 Handling Front-End Events and Alarms Scenario: This application uses many unmanne
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-24 SMS Escalation and Acknowledgement Scenario: In this example we describe how to u
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-25 Step 3: In the THEN settings, select Short Message Service and click the Properti
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-26 Step 5: If the SMS alarm is triggered, an alarm message will be received with the
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-27 SMS Commands for Monitoring and Control Scenario: In this example we specify how
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-28 Enabling the Power Saving Function and Secure Wake on Call Scenario: In this exam
ioLogik Cellular Micro RTU Controller Introduction 1-9 ioLogik W5312/W5312-T Specifications Inputs and Outputs Digital Inputs: 8 channels Digital Ou
ioLogik Cellular Micro RTU Controller Planning and Assistance 5-29 Enabling Ethernet and Cellular Redundancy Scenario: In this example we describe h
A A. Pin-outs and Cable Wiring The following topics are covered in this appendix: Pinouts CN1: SMA, Cellular Antenna Connector CN2: DB9, Ma
ioLogik Cellular Micro RTU Controller Pin-outs and Cable Wiring A-2 Pinouts CN1: SMA, Cellular Antenna Connector CN2: DB9, Male, RS-232 Connector
ioLogik Cellular Micro RTU Controller Pin-outs and Cable Wiring A-3 TB1: Power Input Terminal Block TB2: I/O Terminal Block (W5340) Terminal Block
ioLogik Cellular Micro RTU Controller Pin-outs and Cable Wiring A-4 TB2: I/O Terminal Block (W5312) Terminal Block (Left) Pin Signals 1 DI_COM0 2
ioLogik Cellular Micro RTU Controller Pin-outs and Cable Wiring A-5 PNP Type Sensors Connection Digital Output Sink Mode Relay Output Analog Inpu
B B. SMS Commands SMS commands help users use short messages to monitor or control the I/O status of an ioLogik W5300 Micro RTU Controller system. T
ioLogik Cellular Micro RTU Controller SMS Commands B-2 SMS Command Syntax: #GetSMS?command_channel=?&command_channel=?...# #SetSMS?command_chann
ioLogik Cellular Micro RTU Controller SMS Commands B-3 Local I/O Commands: SMS Command Attribute Note AIEnable_CH Read AI channel is enabled o
ioLogik Cellular Micro RTU Controller SMS Commands B-4 Expansion I/O Commands: SMS Command Attribute Note EXP_DEV_AIValue_CH Read Expansion AI
ioLogik Cellular Micro RTU Controller Introduction 1-10 Accuracy: • ±0.1% FSR @ 25°C • ±0.3% FSR @ -30 and 70°C Sampling Rate: W5340: • All channels
ioLogik Cellular Micro RTU Controller SMS Commands B-5 EXP_DEV_RTDType_CH Read Expansion RTD Type DEV=Device slot number, start index:01 CH = Chan
C C. Modbus/TCP Address Mappings The system Modbus Address can be separated into two parts, one for the ioLogik W5300 and the other for the expansio
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-2 NOTE For Modbus addresses of the ioLogik E1200 expansion modules attached to t
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-3 00061 0x003C 1 bit CH0 DO Safe Pulse Operate Status 0: Off 1: On 00062 0x0
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-4 1 : Overflow Write : 0 : clear overflow status 1 : return Illegal
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-5 Power-off storage enable ON/OFF 1:ON 0:OFF 00146 0x0091 1 bit CH1 DI set ch
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-6 0: INPUT (Default: OUTPUT) // AI Channel Reference Address Data T
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-7 3xxxx Read only Registers (supports function 4) Reference Address Data Type
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-8 40007 0x0006 1 word CH3 DO Pulse Output Count Value Hi- Word 40008 0x0007
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-9 40068 0x0043 1 word CH9 DO Pulse High Signal Width Lo- Word (Relay) 40073
ioLogik Cellular Micro RTU Controller Introduction 1-11 Time: ioLogik W5340: 196,561 hrs ioLogik W5340-HSDPA/W5348-HSDPA-C: 280,739 hrs Database: Te
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-10 0: DI 1: Count Others : return Illegal Data Value 40104 0x0067 1 word CH7
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-11 40350 0x015D 1 word Initial Internal Register 13 Value 40351 0x015E 1 wo
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-12 40403 0x0192 1 word Timer Interval 18 Value 40404 0x0193 1 word Timer I
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-13 40426 0x01C7 10 word Inernal Register Description 23 Value 40427 0x01C8
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-14 09: 0 -10V Others: return Illegal Data Value 40516 0x0203 1 wo
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-15 03: +/-10V 04: 0-20mA 05: 4-20mA
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-16 419450 0x4BF9 word Get/Set Current Internal Register(Float)_18 Lo-word 4
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-17 419503 0x4C2E word Get/Set Initial Internal Register(Float)_17 Hi-word 4
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-18 5xxxx Write Registers (supports function 8) Sub-function Data Field (Request
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-19 00051 0x0032 1 bit CH2 DO PowerOn Pulse Operate Status 0: Off 1: On 00052
2 2. Getting Started This chapter describes how to install the ioLogik W5300. The following topics are covered in this chapter: Cellular Micro RT
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-20 Write: 1 : Clear counter value 0 : return Illegal Data Value 00092 0x005B
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-21 1 : Overflow Write : 0 : clear overflow status 1 : return Illegal
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-22 00139 0x008A 1 bit CH6 DI Safe Pulse Operate Status 0: Off 1: On 00140 0x
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-23 00165 0x00A4 1 bit DIO 8 Set DIO direction 1: OUTPUT 0: INPUT (
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-24 30021 0x0014 word CH10 DI Counter Value Hi- Word (DIO) 30022 0x0015 word
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-25 34111 0x100E 2 word (ULONG) System Elapsed Time (in sec) 34113 0x1010 1 w
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-26 40036 0x0023 1 word CH5 DO Pulse Low Signal Width Lo- Word 40037 0x0024
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-27 40081 0x0050 1 word CH8 DO Mode 0: DO (DIO) 1: Pulse
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-28 1: Count Others : return Illegal Data Value 40106 0x0069 1 word CH9 DI Mod
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-29 40160 0x009F 1 word CH7 DO set/get safe mode wordvalue 0: Off 1: On 40161
ioLogik Cellular Micro RTU Controller Getting Started 2-2 Cellular Micro RTU Controller Flowchart Before Testing Prepare the following items before
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-30 40204 0x00CB 1 word CH3 DI set/get counter start word 40205 0x00CC 1 wor
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-31 40249 0x00F8 1 word CH0 DI set/get power on start word (PowerOn Counter Op
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-32 40348 0x015B 1 word Internal Register 11 Value 40349 0x015C 1 word Inte
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-33 40401 0x0190 1 word Timer Interval 16 Value 40402 0x0191 1 word Timer I
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-34 40424 0x01C5 10 word Internal Register Description 21 Value 40425 0x01C6
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-35 419444 0x4BF3 word Get/Set Current Internal Register(Float)_15 Lo-word 4
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-36 419497 0x4C28 word Get/Set Initial Internal Register(Float)_14 Hi-word 4
ioLogik Cellular Micro RTU Controller Modbus/TCP Address Mappings C-37 419550 0x4C5D 10 word Get/Set Internal Register(Float)_25 Description 4195
D D. SNMP Agents with MIB II, RS-232-like Groups The ioLogik Cellular Micro RTU Controller has SNMP (Simple Network Management Protocol) agent softw
ioLogik Cellular Micro RTU Controller SNMP Agents with MIB II, RS-232-like Groups D-2 ipRouteDest IcmpOutAddrMaskReps ipRouteIfIndex ipRout
ioLogik Cellular Micro RTU Controller Getting Started 2-3 Laboratory Testing Grounding the Unit The ioLogik is equipped with one grounding point loc
ioLogik Cellular Micro RTU Controller SNMP Agents with MIB II, RS-232-like Groups D-3 snmpOutBadValues snmpOutGenErrs snmpOutGetRequests
ioLogik Cellular Micro RTU Controller SNMP Agents with MIB II, RS-232-like Groups D-4 dio03-Type relay00- HighWidth VC08-Value dio03- Mode relay0
E E. Factory Default Settings The factory default settings for firmware V1.3 for the ioLogik W5312 series, V1.5 for the ioLogik W5340 series, and V1
ioLogik Cellular Micro RTU Controller Factory Default Settings E-2 Module Name: “empty” Module Location: “empty: SNMP: Enable Community: Public Cont
F F. Troubleshooting the Cellular I/O Connection Moxa provides the following checklist as a step-by-step troubleshooting guide. If you still can’t s
ioLogik Cellular Micro RTU Controller Troubleshooting the Cellular I/O Connection F-2 3. What status is shown on ioAdmin’s Cellular Dial Up setting
G G. FAQ The following information is provided as a guide that you can refer to when troubleshooting. If you still can’t solve your problem, please
ioLogik Cellular Micro RTU Controller User’s Manual The software described in this manual is furnished under a license agreement and may be used onl
ioLogik Cellular Micro RTU Controller Getting Started 2-4 Connecting to ioAdmin via Ethernet Configuring the Computer’s IP Address 1. For initial c
ioLogik Cellular Micro RTU Controller Getting Started 2-5 3. if the host computer has multiple interfaces, be sure to select the correct one before
ioLogik Cellular Micro RTU Controller Getting Started 2-6 5. Monitoring and Testing I/O status: Once your unit has been found by ioAdmin, you can v
ioLogik Cellular Micro RTU Controller Getting Started 2-7 Configuring the DIO Channels The ioLogik W5300 product family is equipped with different I
ioLogik Cellular Micro RTU Controller Getting Started 2-8 Digital Input Wet Contact (Connect to NPN-type Sensor) Digital Input Wet Contact (Connect
ioLogik Cellular Micro RTU Controller Getting Started 2-9 ATTENTION When connecting the I/O device to the ioLogik’s dry contacts, we strongly recom
ioLogik Cellular Micro RTU Controller Getting Started 2-10 DIN Rail / Wall Mounting The ioLogik W5300’s built-in mounting appendages are suitable fo
ioLogik Cellular Micro RTU Controller Getting Started 2-11 Installing/Removing the SIM Card and SD Card The ioLogik is equipped with two slots; one
ioLogik Cellular Micro RTU Controller Getting Started 2-12 Connecting the Cellular Micro RTU Controllers over a Cellular Network When the environme
ioLogik Cellular Micro RTU Controller Getting Started 2-13 Detailed instructions: 1. Power off the ioLogik W5300. 2. Insert a SIM card that can co
Table of Contents 1. Introduction ...
ioLogik Cellular Micro RTU Controller Getting Started 2-14 Installing Active OPC Server on a Host that has a Public Static IP Address Moxa’s Active
ioLogik Cellular Micro RTU Controller Getting Started 2-15 Import/Export Configuration File Using ioAdmin to Import/Export the Configuration To impo
3 3. Utility: ioAdmin In this chapter, we explain how to use ioAdmin to configure your ioLogik product. The following topics are covered in this cha
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-2 ioAdmin System Requirements ioLogik Cellular Micro RTU Controllers can be managed and con
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-3 ioAdmin Basic Functions Main Screen Overview This is ioAdmin’s main screen. The main wind
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-4 When importing/exporting a device list, you will be prompted to select which ioLogik on t
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-5 Click Start Search to start searching. Network Interface allows you to select a network t
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-6 COM Port Setting is used to set the default parameters for the ioAdmin utility to establi
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-7 Menu Bar: Sort The Sort menu allows the Devices list in the navigation panel to be sorted
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-8 Menu Bar: Help ioAdmin provides a wiring guide for the ioLogik W5300 series. You can acc
Timer Settings ... 4-10 SNMP Tr
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-9 Navigation Panel A function menu is accessed by right clicking on the server model name i
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-10 Main Window The Main Window allows users to view the I/O status, ioLogik system informat
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-11 Message Monitor Panel (General) The Message Monitor panel will display any TCP/UDP Acti
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-12 ioAdmin Administrator Functions For full access to all configuration options, log in as
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-13 NOTE The server also relates to the node created in the Active OPC Server. LAN Setting
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-14 DNS Settings Use this field to specify the IP addresses of one or two DNS servers. DNS s
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-15 Users can disable the unused AI channel by un-checking the Enable checkbox to incre
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-16 The Reset Min and Reset Max buttons will clear the minimum or maximum values recorded a
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-17 After double-clicking on a virtual channel a popup window will appear (see below). Firs
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-18 Configuring DIO Channels Channels DIO-0 to DIO-7 support both DI and DO channel operati
G. FAQ ...
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-19 Type Logic 0 Logic 1 Dry contact Close to GND open Wet contact 0 to 3 V 10 to 30
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-20 By default, the Event Counter value will be reset to zero if power is disconnected. If y
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-21 In DO mode, the specifications are as follows. Type Logic 0 (OFF) Logic 1 (ON) DO mode
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-22 You can control how a DO/Relay output channel acts when the network is disconnected by u
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-23 Alias Name Alias Name helps users configure the alias of a DI or DO/Relay Output channel
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-24 ATTENTION The expansion module should be installed on the same network segment or the i
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-25 The W5300 micro controller allows you to connect the first expansion module with an Ethe
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-26 Active Tags Panel When logged in as administrator, fill in the fixed IP address on the A
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-27 Active OPC: Redundancy Mode Active Tag offers three Active OPC redundancy Modes: Normal,
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-28 Read/Write Privilege An input channel can only be read while an output channel is shown
1 1. Introduction Moxa’s ioLogik Cellular Micro RTU Controllers are highly integrated, stand-alone solutions designed for remote monitoring applicat
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-29 NOTE: 1. The Virtual Channel is updated periodically, the time interval unit can be set
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-30 Cellular Settings Panel The Cellular Setting includes Dial-up Setting, Caller IDs, Opera
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-31 must reboot in order for the settings to take effect. Connection information is displaye
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-32 DDNS Settings If your cellular service provider offers a public IP address after you con
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-33 NOTE Currently, the ioLogik W5300 supports DNS service as provided by DynDNS. For detail
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-34 Example: Gateway to gateway connection between ioLogik and IPSec servers ioAdmin VPN Se
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-35 Manual Key/ESP SPI: Sets the VPN manual key incoming/outgoing SPI between 257 and 42949
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-36 ISAKMP/PSK Local Identify Pre-Share Key (PSK): Sets the VPN ISAKMP Pre-Shared key setti
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-37 ISAKMP phase 2 Encryption mode: Select the VPN ISAKMP phase 2 encryption mode. Authentic
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-38 NOTE The default setting of the Cellular Reconnection function is disabled, which preve
ioLogik Cellular Micro RTU Controller Introduction 1-2 Quick Start Guide Overview 1. Product Features 2. Product Selection and Specifications 3
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-39 PING Check before system restart: A remote destination is used in this setting to indica
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-40 ATTENTION If the Serial Tunnel setting is used, Cellular Setting Operation Mode Cel
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-41 Watchdog Panel The Watchdog panel is available after you log in as administrator. When e
ioLogik Cellular Micro RTU Controller Utility: ioAdmin 3-42 Changes on the Click&Go Logic panel are not effective until the ioLogik W5300 is res
4 4. Click&Go Logic Click&Go Logic was developed by Moxa to provide an easy way to program your ioLogik W5300 product for Cellular Micro RTU
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-2 Quick Start Guide Overview • Software Overview • Utility Features • Working with
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-3 Overview The ioLogik W5300 series system eliminates the need for host computers to cont
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-4 Click&Go Logic Basics To use Click&Go Logic, start ioAdmin and log on as an ioL
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-5 Working with Rules Rules are the building blocks of your ioLogik Cellular Micro RTU Con
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-6 I/O Configuration ioLogik products are embedded with various types of I/O channels, and
ioLogik Cellular Micro RTU Controller Introduction 1-3 Unlike the static IP requirements of remote devices for Ethernet I/O with a traditional OPC
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-7 ATTENTION On this panel, be sure to select Start under Counter mode parameter on Powe
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-8 Analog Input Mode Selection Analog input channels can use either voltage or current to
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-9 ATTENTION We strongly recommend configuring the alias name for the I/O channel being
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-10 Defining Global Variables Global Variables include Internal Register Settings, Timer S
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-11 Timer Number Initial State Configuration Timer Timer-0 to Timer-23 START, *STOP
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-12 Under Mail Server Settings, you must configure the address of the SMTP server with you
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-13 Active Message Server The Active Message Server configures one or more destination IP
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-14 Working/Off Working Days The Working/OffWorking Days defines the workweek days, hours,
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-15 Data Logging Profile List The Data Logging Profile List defines how to log the I/O dat
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-16 The Schedule settings are extremely flexible and can log by day, week, or month. Spec
ioLogik Cellular Micro RTU Controller Introduction 1-4 Active OPC Server and ioLogik W5300 series products offer “Auto Tag Generation” to eliminate
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-17 6. Click Save. Internal Register (Float) Settings Internal Register(Float) can be us
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-18 Working with Logic Click&Go Logic Basics The Click&Go Logic panel is available
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-19 IF “A” THEN “B”, ELSE “C” For one control logic rule, there are three “A’s” that can b
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-20 IF Conditions IF conditions are events that trigger THEN/ELSE actions. Under the IF co
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-21 DI DI refers to the status of a digital input channel. Edge detection can be used to r
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-22 AI AI refers to the readings of an analog input channel. An analog input value is spec
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-23 Internal Register (Integer) Internal Register (Integer) represents a status flag to li
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-24 In the above figure, the “Used in:” column indicates this Timer is also used in Rule-0
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-25 System Start-up The Click&Go logic provides the IF condition to perform an action,
ioLogik Cellular Micro RTU Controller Click&Go Logic 4-26 DI-0 = OFF to ON DI-1 = OFF to ON DI-2 = OFF to ON Relation between conditions AND