Industrial Secure Router User's Manual Network Redundancy
6-2
Layer 2 Redundant Protocols (EDR-810 series
only)
Configuring STP/RSTP
The following figures indicate which Spanning Tree Protocol parameters can be configured. A more detailed
explanation of each parameter follows.
At the top of this page, the user can check the Current Status of this function. For RSTP, you will see:
Now Active:
It shows which communication protocol is being usedTurbo Ring, RSTP, or neither.
Root/Not Root
This field only appears when RSTP mode is selected. The field indicates whether or not this switch is the Root
of the Spanning Tree (the root is determined automatically).
At the bottom of this page, the user can configure the Settings of this function. For RSTP, you can configure:
Redundancy Protocol
Setting Description Factory Default
Turbo Ring Select this item to change to the Turbo Ring configuration page.
None
RSTP (IEEE
802.1W/1D)
Select this item to change to the RSTP configuration page. None
Bridge priority
Setting Description Factory Default
Numerical value
selected by user
Increase this device’s bridge priority by selecting a lower
number. A device with a higher bridge priority has a greater
chance of being established as the root of the Spanning Tree
topology.
32768
Forwarding Delay (sec.)
Setting Description Factory Default
Numerical value input
by user
The amount of time this device waits before checking to see if it
should change to a different state.
15