The Line-Swap Fast Recovery function, which is enabled by default, allows the EDS-510A to
return to normal operation extremely quickly after devices are unplugged and then re-plugged into
different ports. The recovery time is on the order of a few milliseconds (compare this with
standard commercial switches for which the recovery time could be on the order of several
minutes). To disable the Line-Swap Fast Recovery function, or to re-enable the function after it
has already been disabled, access either the Console utility’s Line-Swap recovery page, or the
Web Browser interface’s Line-Swap fast recovery page, as the following figure shows:
Configuring Line-Swap Fast Recovery
Enable Line-Swap-Fast-Recovery
Setting Description Factory Default
Enable/Disable Select this option to enable the
Line-Swap-Fast-Recovery function
Enable
Using Set Device IP
To reduce the effort required to set up IP addresses, the EDS-510A series comes equipped with
DHCP/BOOTP server and RARP protocol to set up IP addresses of Ethernet-enabled devices
automatically.
When enabled, the Set device IP function allows the EDS-510A to assign specific IP addresses
automatically to connected devices that are equIPped with DHCP Client or RARP protocol. In
effect, the EDS-510A acts as a DHCP server by assigning a connected device with a specific IP
address stored in its internal memory. Each time the connected device is switched on or rebooted,
the EDS-510A sends the device the desired IP address.
Perform the following steps to use the Set device IP function: