OnCell G2100 Series User’s Manual Getting Started
2-10
A terminal block adaptor with power jack connector is provided to connect to AC power instead of
DC power. Compatible AC power adaptors are listed on the Moxa website, www.moxa.com.
ATTENTION
Always install the antenna first and then connect power. Do not connect power if the antenna has
not been installed! Doing so may damage the unit.
Connecting a Serial Device
The RS-232 serial interface come with 15 KV ESD serial line protection and matches the pinouts
of a standard D-shell connector. A serial device or PC COM port can be connected with a DB9(M)
to DB9(F) serial cable, such as Moxa’s CBL-F9M9-150 (100 cm) or CBL-F9M9-20 (20 cm).
Meter
Meter Meter
RS-485 Multi-dropped devices
CBL-F9M9-150 or
CBL-F9M9-20
PC or RS-232 Devices
For OnCell G2150I Only
A separate 5-pin terminal block connector on the bottom panel is used for RS-422, 2-wire RS-485,
and 4-wire RS-485 connections. A built-in 120 terminal resistor can be activated by DIP switch
if required. Pull high/low resistor adjustments are also allowed. Both the RS-232 and RS-422/485
interfaces come with two types of protection: (1) 2.5 KV RMS isolation for 1 min and (2) 15 KV
ESD serial line protection.
ON DP
16
T+
T-
R+/D+ R-/D-
GND
RS-422/485 settings are configured by DIP switch, on the bottom panel.
y Switches 1, 2, and 3 select the serial interface.
y Switch 4 enables or disables the termination resistor.
y Switches 5 and 6 set the pull high/low resistor.
2
5 61
43
ON DIP