Moxa ICF-1150-M-ST Installation Guide Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 9
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
- 8 -
ATTENTION
For Fiber Ring Users:
If the Rx LEDs of the converter glow continuously, remove
the fiber cable and connect again, then the system will not
have the same condition.
NOTE: “Ring Mode” can only be used for half-duplex
applications.
LED Indicators
There are 3 LEDs on the front panel of the ICF-1150.
LED Color Function
PWR Green Steady ON: Power is ON
Fiber Tx Green When sending serial data from the fiber port
Fiber Rx Yellow When receiving data from the fiber port
Specifications
Serial Communication
Signals for RS-232 TxD, RxD, SGND
Signals for RS-422 TxD+, TxD-, RxD+, RxD-, SGND
Signals for 4-wire RS-485 TxD+, TxD-, RxD+, RxD-, SGND
Signals for 2-wire RS-485 Data+, Data-, SGND
Baudrate 50 bps to 921.6 Kbps
ESD protection 15 KV ESD
Fiber Communication
Connector type ST or SC
Distance Single-mode fiber for 40 km
Multi-mode fiber for 5 km
Support Cable : 8.3/125, 8.7/125, 9/125 or 10/125 μm
(single mode)
50/125, 62.5/125, or 100/140 μm
(multimode)
Wavelength ICF-1150-S: 1310 nm
ICF-1150-M: 850 nm
TX Output ICF-1150-S: > -5 dBm
ICF-1150-M: > -5 dBm
RX Sensitivity ICF-1150-S: -25 dBm
ICF-1150-M: -20 dBm
Point-to-Point Transmission Half or Full duplex
Multi-drop Transmission Half duplex, fiber ring
Environmental
Operating Temperature
0 to 60°C (32 to 142°F), 5 to 95 % RH
-40 to 85°C (-40 to 167°F) for –T Model
Storage Temperature -40 to 85°C (-4 to 185°F), 5 to 95 % RH
Power
Input Power Voltage 12 to 48 VDC
Power Line Protection 4 KV Burst (EFT), EN61000-4-4
2 KV Surge, EN61000-4-5
Reverse Power Protection Protects against V+/V- reversal
Over Current Protection Protects against 2 signals shorted together:
1.1A
Power Consumption ICF-1150-S/M-SC/ST: 127 mA @ 12V
Page view 7