ioLogik E1200 Series User’s Manual Fourth Edition, January 2011 www.moxa.com/product © 2011 Moxa Inc. All rights reserved. Reproduction without permi
ioLogik E1200 Series Introduction 1-6 ioLogik E1262 Thermocouple Input Sensor Type: J, K, T, E, R, S, B, N Mili Volt Type: ±78.126 mV, ±39.062 mV,
ioLogik E1200 Series Introduction 1-7 Physical Dimensions 132124842727.8 Unit=mm Hardware Reference Panel Guide NOTE The reset button restarts th
ioLogik E1200 Series Introduction 1-8 Green Ethernet connection enabled Port 1 Flashing Transmitting or receiving data Green Ethernet connection
2 2. Initial Setup This chapter describes how to install the ioLogik E1200. The following topics are covered in this chapter: Hardware Installati
ioLogik E1200 Series Initial Setup 2-2 Hardware Installation Connecting the Power Connect the 12 to 36 VDC power line to the ioLogik E1200’s termin
ioLogik E1200 Series Initial Setup 2-3 Analog mode configuration is as follows (default is Voltage Mode) I/O Wiring Diagrams ATTENTION Remove th
ioLogik E1200 Series Initial Setup 2-4 Software Installation ioSearch is a search utility that helps the user locate ioLogik E1200 devices on th
ioLogik E1200 Series Initial Setup 2-5 If multiple ioLogik E1200 units are installed on the same network, remember that each unit has the same def
3 3. Using the Web Console The ioLogik E1200’s main configuration and management utility is the built-in web console, which can be used to configure
ioLogik E1200 Series Using the Web Console 3-2 Introduction to the Web Console The ioLogik E1200 web console is a browser-based configuration utili
ioLogik E1200 Series User’s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance wi
ioLogik E1200 Series Using the Web Console 3-3 Network Settings General Settings On the General Settings page, you can assign a server name and lo
ioLogik E1200 Series Using the Web Console 3-4 Ethernet Configuration On the Ethernet Configuration page, you can set up a static or dynamic IP add
ioLogik E1200 Series Using the Web Console 3-5 Active OPC Server Settings Refer to the Tag Generation section in Chapter 5: Active OPC Server Lite
ioLogik E1200 Series Using the Web Console 3-6 For Event Counter mode, configure “Lo to Hi,” “Hi to Lo,” or “Both” to trigger the counter. The cou
ioLogik E1200 Series Using the Web Console 3-7 Users may also configure the alias name and the logic definition on this page. ATTENTION Remove th
ioLogik E1200 Series Using the Web Console 3-8 ATTENTION Remove the screw on the back panel and open the cover to configure the jumpers to select
ioLogik E1200 Series Using the Web Console 3-9 AO Channels The current status of each AO (analog output) channel can be viewed on the AO Channel pa
ioLogik E1200 Series Using the Web Console 3-10 RTD Channels The current status of each RTD (Resistance Temperature Detector) channel can be viewed
ioLogik E1200 Series Using the Web Console 3-11 TC Channels The current status of each TC (Thermocouple) channel can be viewed on the TC Channel p
ioLogik E1200 Series Using the Web Console 3-12 The ioLogik E1200 allows you to manually adjust the current temperature reading. In each channel co
Table of Contents 1. Introduction...
ioLogik E1200 Series Using the Web Console 3-13 Allowed Hosts IP address/Netmask 192.168.0.1 to 192.168.255.254 192.168.0.0 / 255.255.0.0 192.168
ioLogik E1200 Series Using the Web Console 3-14 Peer-to-peer Settings Peer-to-peer Settings (1-50) The ioLogik E1200 supports up to 50 peer-to-pee
ioLogik E1200 Series Using the Web Console 3-15 Client settings: Note: refer to the table below for maximum number of rules supported at different
ioLogik E1200 Series Using the Web Console 3-16 ATTENTION If you forget the password, the ONLY way to configure the ioLogik E1200 is by using the
4 4. Using ioSearch This chapter describes ioSearch, which is used to search for and locate ioLogik E1200 units. The following topics are covered in
ioLogik E1200 Series Using ioSearch 4-2 Introduction to ioSearch ioSearch is for locating or searching for an Logik E1200 on the physical network.
ioLogik E1200 Series Using ioSearch 4-3 Network Interface allows you to select a network to use, if the PC has multiple network adaptors installed
ioLogik E1200 Series Using ioSearch 4-4 Quick Links Quick links are provided to search for I/O servers on the network and sort the server list. 1
ioLogik E1200 Series Using ioSearch 4-5 ATTENTION Do not interrupt the firmware update process! An interruption in the process may result in your
ioLogik E1200 Series Using ioSearch 4-6 Export The export function is used to export the current configuration file of an ioLogik E1200. The expor
5. Active OPC Server Lite ... 5-1
ioLogik E1200 Series Using ioSearch 4-7 Reset to Default Select this function to reset all settings, including console password, to factory def
5 5. Active OPC Server Lite This chapter explains how to use the web console of the ioLogik E1200 to connect to the Active OPC Server Lite package.
ioLogik E1200 Series Active OPC Server Lite 5-2 Introduction to Active OPC Server Lite Moxa’s Active OPC Server Lite is a software package operated
ioLogik E1200 Series Active OPC Server Lite 5-3 Active OPC Server Lite Main Screen Overview Active OPC Server Lite’s main screen displays a figure
ioLogik E1200 Series Active OPC Server Lite 5-4 System Several operations can be accessed from the System menu. Network Interface allows users to
ioLogik E1200 Series Active OPC Server Lite 5-5 Sort The Sort menu allows the server list in the navigation panel to be sorted by connection and ty
ioLogik E1200 Series Active OPC Server Lite 5-6 Click the “Submit” button and click the Save/Restart button on the next page. On the Create AOPC
ioLogik E1200 Series Active OPC Server Lite 5-7 Read/Write Privilege An input channel can only be read while an output channel shows “read/write
ioLogik E1200 Series Active OPC Server Lite 5-8 Click Item Browse and select the channel that needs to be monitored. To write to the output
ioLogik E1200 Series Active OPC Server Lite 5-9
1 1. Introduction The ioLogik E1200 series is a stand-alone remote Ethernet I/O server that can connect sensors and on/off switches for automation a
A A. Modbus/TCP Default Address Mappings The following topics are covered in this appendix: E1210 Modbus Mapping E1211 Modbus Mapping E1212
ioLogik E1200 Series Modbus/TCP Default Address Mappings A-2 NOTE The Modbus/TCP ID of the ioLogik E1200 is set to “1” by default. E1210 Modbus M
ioLogik E1200 Series Modbus/TCP Default Address Mappings A-3 00280 0x0117 1 bit CH7 DI Clear Count Value Read Always return:0 Write: 1
ioLogik E1200 Series Modbus/TCP Default Address Mappings A-4 10014 0x000D 1 bit CH13 DI Value,0=OFF,1=ON (Read only) 10015 0x000E 1 bit CH14 DI Val
ioLogik E1200 Series Modbus/TCP Default Address Mappings A-5 00003 0x0002 1 bit CH2 DO Value 0: Off 1: On 00004 0x0003 1 bit CH3 DO Val
ioLogik E1200 Series Modbus/TCP Default Address Mappings A-6 00023 0x0016 1 bit CH6 DO Pulse Operate Status 0: Off 1: On 00024 0x0017 1 bit C
ioLogik E1200 Series Modbus/TCP Default Address Mappings A-7 0 : Return illegal data value(0x03) 00282 0x0119 1 bit CH9 DI Clear Count Value R
ioLogik E1200 Series Modbus/TCP Default Address Mappings A-8 3xxxx Read Only Registers (Function 4) Reference Address Data Type Description 30018
ioLogik E1200 Series Modbus/TCP Default Address Mappings A-9 E1214 Modbus Mapping 0xxxx Read/Write Coils (Functions 1, 5, 15) Reference Address Da
ioLogik E1200 Series Modbus/TCP Default Address Mappings A-10 1xxxx Read Only Coils (Function 2) Reference Address Data Type Description 10001 0x0
ioLogik E1200 Series Introduction 1-2 Product Model Information Model Description ioLogik E1210 Remote Ethernet I/O with 2-port Ethernet switch an
ioLogik E1200 Series Modbus/TCP Default Address Mappings A-11 E1240 Modbus Mapping 3xxxx Read Only Registers (Function 4) Reference Address Data T
ioLogik E1200 Series Modbus/TCP Default Address Mappings A-12 E1242 Modbus Mapping 0xxxx Read/Write Coils (Functions 1, 5, 15) Reference Address D
ioLogik E1200 Series Modbus/TCP Default Address Mappings A-13 00276 0x0113 1 bit CH7 DI Clear Count Value Read Always return:0 Write:
ioLogik E1200 Series Modbus/TCP Default Address Mappings A-14 4xxxx Read/Write Registers (Functions 3, 6, 16) Reference Address Data Type Descript
ioLogik E1200 Series Modbus/TCP Default Address Mappings A-15 32065 0x0810 1 word CH8 TC Minimum Value Hi Word 32066 0x0811 1 word CH8 TC M
B B. Network Port Numbers ioLogik E1200 Network Port Usage Port Type Usage 80 TCP Web console service 502 TCP Modbus/TCP communication 68 UDP BO
C C. Factory Defaults ioLogik E1200 series products are configured with the following factory defaults: Default IP address: 192.168.127.254 Default
D D. Pinouts Pin assignment of Terminal blocks ioLogik E1211 (top to bottom)1 COM 02 DI03 DI14 DI25 DI36 GND7 DI48 DI59 DI610 DI711 COM 112 DI813 D
E E. FCC Interference Statement Federal Communication Commission Warning! This equipment has been tested and found to comply with the limits for a C
F F. European Community (CE) This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user
ioLogik E1200 Series Introduction 1-3 MTBF (meantime between failures) Time: 671,345 hrs Database: Telcordia (Bellcore) ioLogik E1211 Digital Outpu
ioLogik E1200 Series Introduction 1-4 Wet Contact: • Logic 0: 0 to 3 VDC • Logic 1: 10 to 30 VDC (DI COM to DI) Isolation: 3K VDC or 2K Vrms Counte
ioLogik E1200 Series Introduction 1-5 ioLogik E1242 Analog Input Type: Differential input Resolution: 16 bits I/O Mode: Voltage / Current Input Ran
Comments to this Manuals