ioLogik E1200 Series User’s Manual
Fourth Edition, January 2011
www.moxa.com/product
© 2011 Moxa Inc. All rights reserved.
Reproduction without permission is prohibited.
Page view 0
1 2 3 4 5 6 ... 68 69

Summary of Contents

Page 1 - Fourth Edition, January 2011

ioLogik E1200 Series User’s Manual Fourth Edition, January 2011 www.moxa.com/product © 2011 Moxa Inc. All rights reserved. Reproduction without permi

Page 2 - Disclaimer

ioLogik E1200 Series Introduction 1-6 ioLogik E1262 Thermocouple Input Sensor Type: J, K, T, E, R, S, B, N Mili Volt Type: ±78.126 mV, ±39.062 mV,

Page 3 - Table of Contents

ioLogik E1200 Series Introduction 1-7 Physical Dimensions 132124842727.8 Unit=mm Hardware Reference Panel Guide NOTE The reset button restarts th

Page 4

ioLogik E1200 Series Introduction 1-8 Green Ethernet connection enabled Port 1 Flashing Transmitting or receiving data Green Ethernet connection

Page 5 - Introduction

2 2. Initial Setup This chapter describes how to install the ioLogik E1200. The following topics are covered in this chapter:  Hardware Installati

Page 6 - Product Specifications

ioLogik E1200 Series Initial Setup 2-2 Hardware Installation Connecting the Power Connect the 12 to 36 VDC power line to the ioLogik E1200’s termin

Page 7

ioLogik E1200 Series Initial Setup 2-3 Analog mode configuration is as follows (default is Voltage Mode) I/O Wiring Diagrams ATTENTION Remove th

Page 8

ioLogik E1200 Series Initial Setup 2-4 Software Installation ioSearch is a search utility that helps the user locate ioLogik E1200 devices on th

Page 9

ioLogik E1200 Series Initial Setup 2-5 If multiple ioLogik E1200 units are installed on the same network, remember that each unit has the same def

Page 10 - Common Specifications

3 3. Using the Web Console The ioLogik E1200’s main configuration and management utility is the built-in web console, which can be used to configure

Page 11 - Hardware Reference

ioLogik E1200 Series Using the Web Console 3-2 Introduction to the Web Console The ioLogik E1200 web console is a browser-based configuration utili

Page 12

ioLogik E1200 Series User’s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance wi

Page 13 - Initial Setup

ioLogik E1200 Series Using the Web Console 3-3 Network Settings General Settings On the General Settings page, you can assign a server name and lo

Page 14 - Hardware Installation

ioLogik E1200 Series Using the Web Console 3-4 Ethernet Configuration On the Ethernet Configuration page, you can set up a static or dynamic IP add

Page 15 - I/O Wiring Diagrams

ioLogik E1200 Series Using the Web Console 3-5 Active OPC Server Settings Refer to the Tag Generation section in Chapter 5: Active OPC Server Lite

Page 16 - Software Installation

ioLogik E1200 Series Using the Web Console 3-6 For Event Counter mode, configure “Lo to Hi,” “Hi to Lo,” or “Both” to trigger the counter. The cou

Page 17 - Load Factory Default

ioLogik E1200 Series Using the Web Console 3-7 Users may also configure the alias name and the logic definition on this page. ATTENTION Remove th

Page 18 - Using the Web Console

ioLogik E1200 Series Using the Web Console 3-8 ATTENTION Remove the screw on the back panel and open the cover to configure the jumpers to select

Page 19 - Overview

ioLogik E1200 Series Using the Web Console 3-9 AO Channels The current status of each AO (analog output) channel can be viewed on the AO Channel pa

Page 20 - Network Settings

ioLogik E1200 Series Using the Web Console 3-10 RTD Channels The current status of each RTD (Resistance Temperature Detector) channel can be viewed

Page 21 - Default Address

ioLogik E1200 Series Using the Web Console 3-11 TC Channels The current status of each TC (Thermocouple) channel can be viewed on the TC Channel p

Page 22 - I/O Settings

ioLogik E1200 Series Using the Web Console 3-12 The ioLogik E1200 allows you to manually adjust the current temperature reading. In each channel co

Page 23 - DO Channels

Table of Contents 1. Introduction...

Page 24 - AI Channels

ioLogik E1200 Series Using the Web Console 3-13 Allowed Hosts IP address/Netmask 192.168.0.1 to 192.168.255.254 192.168.0.0 / 255.255.0.0 192.168

Page 25 - ATTENTION

ioLogik E1200 Series Using the Web Console 3-14 Peer-to-peer Settings Peer-to-peer Settings (1-50) The ioLogik E1200 supports up to 50 peer-to-pee

Page 26 - AO Channels

ioLogik E1200 Series Using the Web Console 3-15 Client settings: Note: refer to the table below for maximum number of rules supported at different

Page 27 - RTD Channels

ioLogik E1200 Series Using the Web Console 3-16 ATTENTION If you forget the password, the ONLY way to configure the ioLogik E1200 is by using the

Page 28 - TC Channels

4 4. Using ioSearch This chapter describes ioSearch, which is used to search for and locate ioLogik E1200 units. The following topics are covered in

Page 29 - System Management

ioLogik E1200 Series Using ioSearch 4-2 Introduction to ioSearch ioSearch is for locating or searching for an Logik E1200 on the physical network.

Page 30 - Export System Config

ioLogik E1200 Series Using ioSearch 4-3 Network Interface allows you to select a network to use, if the PC has multiple network adaptors installed

Page 31 - Peer-to-peer Settings

ioLogik E1200 Series Using ioSearch 4-4 Quick Links Quick links are provided to search for I/O servers on the network and sort the server list. 1

Page 32 - Change Password

ioLogik E1200 Series Using ioSearch 4-5 ATTENTION Do not interrupt the firmware update process! An interruption in the process may result in your

Page 33 - Save/Restart

ioLogik E1200 Series Using ioSearch 4-6 Export The export function is used to export the current configuration file of an ioLogik E1200. The expor

Page 34 - Using ioSearch

5. Active OPC Server Lite ... 5-1

Page 35 - Main Items

ioLogik E1200 Series Using ioSearch 4-7 Reset to Default Select this function to reset all settings, including console password, to factory def

Page 36

5 5. Active OPC Server Lite This chapter explains how to use the web console of the ioLogik E1200 to connect to the Active OPC Server Lite package.

Page 37 - Main Function

ioLogik E1200 Series Active OPC Server Lite 5-2 Introduction to Active OPC Server Lite Moxa’s Active OPC Server Lite is a software package operated

Page 38 - Import

ioLogik E1200 Series Active OPC Server Lite 5-3 Active OPC Server Lite Main Screen Overview Active OPC Server Lite’s main screen displays a figure

Page 39 - Restart System

ioLogik E1200 Series Active OPC Server Lite 5-4 System Several operations can be accessed from the System menu. Network Interface allows users to

Page 40 - Reset to Default

ioLogik E1200 Series Active OPC Server Lite 5-5 Sort The Sort menu allows the server list in the navigation panel to be sorted by connection and ty

Page 41 - Active OPC Server Lite

ioLogik E1200 Series Active OPC Server Lite 5-6 Click the “Submit” button and click the Save/Restart button on the next page. On the Create AOPC

Page 42

ioLogik E1200 Series Active OPC Server Lite 5-7 Read/Write Privilege An input channel can only be read while an output channel shows “read/write

Page 43 - Menu Items

ioLogik E1200 Series Active OPC Server Lite 5-8 Click Item  Browse and select the channel that needs to be monitored. To write to the output

Page 44

ioLogik E1200 Series Active OPC Server Lite 5-9

Page 45 - Tag Generation

1 1. Introduction The ioLogik E1200 series is a stand-alone remote Ethernet I/O server that can connect sensors and on/off switches for automation a

Page 46 - Heartbeat Interval

A A. Modbus/TCP Default Address Mappings The following topics are covered in this appendix:  E1210 Modbus Mapping  E1211 Modbus Mapping  E1212

Page 47 - OPC Test Client

ioLogik E1200 Series Modbus/TCP Default Address Mappings A-2 NOTE The Modbus/TCP ID of the ioLogik E1200 is set to “1” by default. E1210 Modbus M

Page 48

ioLogik E1200 Series Modbus/TCP Default Address Mappings A-3 00280 0x0117 1 bit CH7 DI Clear Count Value Read Always return:0 Write: 1

Page 49

ioLogik E1200 Series Modbus/TCP Default Address Mappings A-4 10014 0x000D 1 bit CH13 DI Value,0=OFF,1=ON (Read only) 10015 0x000E 1 bit CH14 DI Val

Page 50

ioLogik E1200 Series Modbus/TCP Default Address Mappings A-5 00003 0x0002 1 bit CH2 DO Value 0: Off 1: On 00004 0x0003 1 bit CH3 DO Val

Page 51 - E1210 Modbus Mapping

ioLogik E1200 Series Modbus/TCP Default Address Mappings A-6 00023 0x0016 1 bit CH6 DO Pulse Operate Status 0: Off 1: On 00024 0x0017 1 bit C

Page 52

ioLogik E1200 Series Modbus/TCP Default Address Mappings A-7 0 : Return illegal data value(0x03) 00282 0x0119 1 bit CH9 DI Clear Count Value R

Page 53 - E1211 Modbus Mapping

ioLogik E1200 Series Modbus/TCP Default Address Mappings A-8 3xxxx Read Only Registers (Function 4) Reference Address Data Type Description 30018

Page 54 - E1212 Modbus Mapping

ioLogik E1200 Series Modbus/TCP Default Address Mappings A-9 E1214 Modbus Mapping 0xxxx Read/Write Coils (Functions 1, 5, 15) Reference Address Da

Page 55

ioLogik E1200 Series Modbus/TCP Default Address Mappings A-10 1xxxx Read Only Coils (Function 2) Reference Address Data Type Description 10001 0x0

Page 56

ioLogik E1200 Series Introduction 1-2 Product Model Information Model Description ioLogik E1210 Remote Ethernet I/O with 2-port Ethernet switch an

Page 57

ioLogik E1200 Series Modbus/TCP Default Address Mappings A-11 E1240 Modbus Mapping 3xxxx Read Only Registers (Function 4) Reference Address Data T

Page 58 - E1214 Modbus Mapping

ioLogik E1200 Series Modbus/TCP Default Address Mappings A-12 E1242 Modbus Mapping 0xxxx Read/Write Coils (Functions 1, 5, 15) Reference Address D

Page 59

ioLogik E1200 Series Modbus/TCP Default Address Mappings A-13 00276 0x0113 1 bit CH7 DI Clear Count Value Read Always return:0 Write:

Page 60 - E1241 Modbus Mapping

ioLogik E1200 Series Modbus/TCP Default Address Mappings A-14 4xxxx Read/Write Registers (Functions 3, 6, 16) Reference Address Data Type Descript

Page 61 - E1242 Modbus Mapping

ioLogik E1200 Series Modbus/TCP Default Address Mappings A-15 32065 0x0810 1 word CH8 TC Minimum Value Hi Word 32066 0x0811 1 word CH8 TC M

Page 62

B B. Network Port Numbers ioLogik E1200 Network Port Usage Port Type Usage 80 TCP Web console service 502 TCP Modbus/TCP communication 68 UDP BO

Page 63 - E1262 Modbus Mapping

C C. Factory Defaults ioLogik E1200 series products are configured with the following factory defaults: Default IP address: 192.168.127.254 Default

Page 64

D D. Pinouts Pin assignment of Terminal blocks ioLogik E1211 (top to bottom)1 COM 02 DI03 DI14 DI25 DI36 GND7 DI48 DI59 DI610 DI711 COM 112 DI813 D

Page 65 - Network Port Numbers

E E. FCC Interference Statement Federal Communication Commission Warning! This equipment has been tested and found to comply with the limits for a C

Page 66 - Factory Defaults

F F. European Community (CE) This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user

Page 67 - Pinouts

ioLogik E1200 Series Introduction 1-3 MTBF (meantime between failures) Time: 671,345 hrs Database: Telcordia (Bellcore) ioLogik E1211 Digital Outpu

Page 68 - FCC Interference Statement

ioLogik E1200 Series Introduction 1-4 Wet Contact: • Logic 0: 0 to 3 VDC • Logic 1: 10 to 30 VDC (DI COM to DI) Isolation: 3K VDC or 2K Vrms Counte

Page 69 - European Community (CE)

ioLogik E1200 Series Introduction 1-5 ioLogik E1242 Analog Input Type: Differential input Resolution: 16 bits I/O Mode: Voltage / Current Input Ran